Loading... Please wait...

Products

Our Newsletter


BC Biomedical SA-2010S Biomedical Safety Analyzer

  • Image 1
Price:
Contact us for pricing and availability
SKU:
BC SA-2010S
Brand:
Weight:
3.00 LBS
Bookmark and Share


Product Description

 

BC Biomedical SA-2010S Biomedical Safety Analyzer

 

  • Line voltage readout
  • Earth/ground lead resistance/leakage current
  • External resistance
  • External leakage current
  • Source receptacle wiring integrity monitor
  • True RMS measurements
  • AAMI ES1-1993 or IEC 601 Selectable
  • Full 20 amp rating
  • Touch control keys
  • LED status indicators
  • Audio feedback
  • Externally replaceable ground fuse
  • Automatic load reversal delay
  •  

    The SA-2000 Series is a microprocessor based electrical safety analyzer family. There are 5 models that provide everything from the most basic testing functions to the most complete set of features of any handheld unit on the market.The compact size makes the SA-2000 family easy to hold and operate. All models operate from 85 to 265 Volts @ 50/60 Hz, with Load Currents up to 20 Amps, so there is no need to purchase 2 different analyzers to cover your testing needs. The SA-2010S is the smallest safety analyzer available with a built-in ECG patient simulator. The SA-2000 family of safety analyzers allows the user to chose the model that best fits the application. The combination of the best features at the best price makes this family of products a natural choice. All models come with a soft case and chassis (black) cable.

     



      SA-2000 SA-2001 SA-2005 SA-2010 SA-2010S
    Voltage (input) 85 to 265 85 to 265 85 to 265 85 to 265 85 to 265
    Current (rating) 20 20 20 20 20
    Measures          
    Voltage (VAC) No 85 to 265 (±3% R)      
    Current (Amps) No 0 to 19.99 (±5% R)      
    Leakage Current (µa) 0 to 1999 DC & 25 to 1kHz (±1% R)        
    1kHz to 100 kHz (± 2.5% R)          
    100kHz to 1mHz (±5% R)          
    Resistance (Ohms) 0 to 19.99 (±1% R)        
    10mA          
    Patient Leads 0 0 5 10 10
    MAP (Isolation) No No Yes Yes Yes
    Built-in ECG Simulator No No No No Yes
    AAMI & IEC Leads AAMI only Yes Yes Yes Yes
    Point-to-Point No Yes Yes Yes Yes
    Test Points No Yes Yes Yes Yes
    Test Capability          
    Open Ground Yes Yes Yes Yes Yes
    Reverse Polarity Yes Yes Yes Yes Yes
    Open Neutral Yes Yes Yes Yes Yes
    Open Line Yes Yes Yes Yes Yes
               